Skip to content
News
News

Customer Information – Discontinuation of V7G24 and Transition to V7GA0

We would like to inform you of the planned discontinuation of our FKM material V7G24, expected to take place at the end of 2027, and the introduction of its successor, V7GA0.

Backround to the material changeover
Due to current developments surrounding the PFAS issue, an increasing number of FKM manufacturers are adapting their production processes. In particular, there is a growing trend away from the use of PFAS-based process aids, such as fluorinated surfactants in polymerisation. As part of these changes, existing FKM compounds are increasingly being phased out by compound manufacturers.

Availability and Stockpiling of V7G24
The current material, V7G24, is expected to remain available until the end of 2027. As things stand, orders can be accepted until approximately the
end of the third quarter of 2027, subject to availability in the upstream supply chain. Particularly for applications that have already been approved or where type testing have been carried out, we recommend early demand planning and, where necessary, appropriate stockpiling to ensure sufficient supply and security of supply during the transition phase. 

Successor material   V7GA0
With our V7GA0 material, we offer you a suitable alternative with comparable or virtually identical technical properties. The new material is based on so-called NFS (Non-Fluoro-Surfactant) technology, which does not use fluorinated surfactants as process aids. However, it remains a fluoropolymer, meaning it will still be subject to the planned PFAS ban. The existing approvals and test results in accordance with DIN EN 549 and BAM will also be available for the new material. The relevant documentation is expected to be available in the coming weeks or months, depending on the processing times of the testing institutes.

Technical assessment and support with the transition
As you can see from the appendix, both materials are bisphenol-crosslinked FKM. Furthermore, the mechanical properties determined from test specimens – both in the new condition and after ageing – show almost identical results, which is why we classify V7GA0 as an equivalent replacement for V7G24. We recommend that you assess the transition at an early stage, taking your specific application conditions and approval requirements into account. We would be happy to assist you with the transition and kindly request that you coordinate with us in good time regarding any required sample parts, test quantities and possible approval processes.
We ask for your understanding regarding this change, which is unfortunately necessary due to market conditions.
For technical enquiries and support with the material changeover, please do not hesitate to contact our Technical Department or your sales representative.